ORIGINAL ARTICLE
Year : 2018  |  Volume : 9  |  Issue : 1  |  Page : 70

Phytoremediation of formaldehyde from indoor environment by ornamental plants: An approach to promote occupants health


Department of Environmental Health Engineering, Environmental Research Center, Isfahan University of Medical Sciences, Isfahan, Iran

Date of Submission24-Jul-2016
Date of Acceptance28-May-2017
Date of Web Publication14-Aug-2018

Correspondence Address:
Yaghoub Hajizadeh
Department of Environmental Health Engineering, Environmental Research Center, Isfahan University of Medical Sciences, Isfahan
Iran
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ijpvm.IJPVM_269_16

Rights and Permissions
  Abstract 


Background: Formaldehyde is a common hazardous indoor air pollutant which recently raised public concerns due to its well-known carcinogenic effects on human. The aim of this study was to investigate a potted plant-soil system ability in formaldehyde removal from a poor ventilated indoor air to promote dwellers health. Methods: For this purpose, we used one of the common interior plants from the fern species (Nephrolepis obliterata), inside a Plexiglas chamber under controlled environment. Entire plant removal efficiency and potted soil/roots contribution were determined by continuously introducing different formaldehyde vapor concentrations to the chamber (0.6–11 mg/m3) each over a 48-h period. Sampling was conducted from inlet and outlet of the chamber every morning and evening over the study period, and the average of each stage was reported. Results: The results showed that the N. obliterata plant efficiently removed formaldehyde from the polluted air by 90%–100%, depending on the inlet concentrations, in a long time exposure. The contribution of the soil and roots for formaldehyde elimination was 26%. Evaluation of the plant growing characteristics showed that the fumigation did not affect the chlorophyll content, carotenoid, and average height of the plant; however, a decrease in the plant water content was observed. Conclusions: According to the results of this study, phytoremediation of volatile organic compound-contaminated indoor air by the ornamental potted plants is an effective method which can be economically applicable in buildings. The fern species tested here had high potential to improve interior environments where formaldehyde emission is a health concern.

Keywords: Formaldehyde, indoor air pollution, phytoremediation, potted plant


How to cite this article:
Teiri H, Pourzamzni H, Hajizadeh Y. Phytoremediation of formaldehyde from indoor environment by ornamental plants: An approach to promote occupants health. Int J Prev Med 2018;9:70

How to cite this URL:
Teiri H, Pourzamzni H, Hajizadeh Y. Phytoremediation of formaldehyde from indoor environment by ornamental plants: An approach to promote occupants health. Int J Prev Med [serial online] 2018 [cited 2019 May 23];9:70. Available from: http://www.ijpvmjournal.net/text.asp?2018/9/1/70/239004




  Introduction Top


Nowadays, indoor air pollution has become a major concern due to its known harmful effects on human health.[1] With the onset of the energy crisis, changes in the building's design owing to energy-efficient strategy, a confined space for house and workplace is provided which reduce the air exchange rate (AER) and increase indoor air pollution.[2],[3],[4],[5],[6] The environmental protection agency (EPA) of the United States has mentioned that indoor air pollutants can be found at a higher concentration than outdoor.[7] However, monitoring and regulating of indoor air pollutants have been neglected behind the outdoor air pollutants.

One of the major indoor air pollutants is formaldehyde with a chemical formula of HCHO. It is one of the most well-known volatile organic compounds (VOCs) associated with indoor air pollution which is attracted public attention worldwide due to its adverse health effects.[3],[8] Formaldehyde is a colorless gas with a strong odor which is soluble in water, as well as it can be smothering at room temperature.[7] The main indoor sources of formaldehyde are from furniture and materials which widely used in the construction of inside the house such as fiberboard and laminated wood, carpets, curtains, rubber, oil-based paint, adhesive materials, cosmetics, electronic devices, and paper products.[2],[9],[10] Furthermore, people are exposed to formaldehyde from combustion sources such as tobacco smoke, gas, petrol, and solid fuels.[11] Typically, in newly built or refurbished residences the levels of formaldehyde are often so high compared to old buildings.[12],[13] Formaldehyde levels generally decrease with the product age,[2],[11],[14] however, according to Wolverton, 10 years is too much time to breath this carcinogenic chemical into lungs.[15]

The World Health Organization has reported that the health effects associated with acute exposure to indoor concentrations of formaldehyde include eye irritation, eye redness, frequent blinking, and irritation in the upper respiratory system.[16] Furthermore, it has been reported that formaldehyde can cause long-term effects such as cancer, leukemia in children, premature birth, low birth weight, congenital anomalies, genotoxicity, and Alzheimer's disease. EPA considers formaldehyde as a probable human carcinogen (Group B1).[2],[7],[17] It has been suggested that occupational exposure to formaldehyde may increase the risk of nasopharyngeal carcinoma. Thus, physician working in the operating theater remains alert to formaldehyde hazards among health-care workers.[18]

At present, there are some techniques for eliminating formaldehyde from the indoor air such as biological methods, adsorption on activated carbon fibers, photocatalytic oxidation, and biofiltration; nevertheless, none of them are fully satisfactory due to low concentrations as well as the volatile characteristic of this chemical.[19],[20],[21],[22] Beside this, increasing the ventilation rate is difficult and not economical for public. Phytoremediation has attracted much consideration in recent decades probably due to it's environmental, economic and social benefits. In addition, it is potential to help zero emission in both traditional and new buildings.[23],[24]

Numerous plants can remove formaldehyde from indoor air.[2],[25],[26] Plant leaves uptakes formaldehyde through stomata and the cuticle, and younger leaves readily absorb the formaldehyde vapors.[3],[27] Besides, some researches have shown that soil microorganisms are capable of degrading pollutants and this degradation is suggested to be encouraged by root exudates.[28],[29],[30] When Formaldehyde is absorbed, one part of it is oxidized into carbon dioxide in the Calvin cycle while the other is combined into the organism such as amino acids, lipids, free sugars, organic acids, and cell-wall components.[3],[10]

This study was conducted with the aim of determination of formaldehyde removal efficiency from indoor air by a potted plant using a pilot scale chamber made of Plexiglas. For this purpose, Nephrolepis obliterata plant (sword fern) from Lomariopsidaceae's family was used. This plant is hugely available throughout Iran and can be acclimatized with the indoor environment. In this work, formaldehyde was used as a common VOC contaminant in indoor, but these methods can be practical to other VOCs.[31]


  Methods Top


Test chamber and experimental setup

Experiments were conducted in a Plexiglas chamber with a volume of 375 L (84 cm length × 62 cm width × 72 cm height) which was made perfectly air-tight. A door was provided in front of the chamber which was sealed by adhesive foam-rubber insulation tape and adjustable metal clips. Two PC fan (Model: 350 XA, 2.03P4) fixed inside the chamber to provide complete mixing of fumigated air. The temperature and relative humidity (RH) of the chamber were controlled by a digital thermometer [Figure 1]. The light intensity supposed to be natural indoor environment light which was measured around the chamber in five directions (west, east, north, south, and above the chamber) four times a day over experimental period using a YF-170 digital light meter (Tenmars Electronics Co., Ltd, Taiwan).
Figure 1: Schematic of the experimental setup: (1) air pump, (2) activated carbon column, (3) formaldehyde solution (37%) vessel, (4) humidifier vessel, (5) mixing vessel, (6) flow meter, (7) gas sampling port, (8) test chamber, (9) air mixing fan, (10) temperature and humidity sensor, (11) sampling impingers, (12) extraction

Click here to view


[Figure 1] shows the experimental setup for this study. The system was consisted of three main parts including (I) the chamber for placement of plants to contact with air stream containing formaldehyde; (II) air pump connected to a flow meter and impingers system which supplies air, water vapor and formaldehyde gas mixture with desired concentration; and (III) sampling system from chamber inlet and outlet for analysis of formaldehyde concentration that include a vacuum pump, flow meter, dual impingers containing liquid absorbent. Stainless steel and silicon tubing were used to connect the system compartments.

Formaldehyde measurement

Formaldehyde vapor was introduced to the chamber by a gas bubbler containing 37% formaldehyde solution.[2] Air was provided by a vacuum pump (Model: ACO-5504, 5w), and the air flows were measured by needle valve glass flow meter (CT Platon, France). In addition, air stream was passed through an activated carbon column to adsorb any potential contaminants. The formaldehyde concentration was measured according to the NIOSH-3500 method, a visible absorption spectrometry technique, using a DR5000 Spectrophotometer (DOC022.53.00654-HACH Lange, Co. USA). This is the most sensitive formaldehyde analysis method capable of detecting as low as 0.1 ppm which is best suited for the determination of formaldehyde in the environmental samples.[32]

Plant materials

In this research, one of the fern species from Lomariopsidaceae's family, Kimberly Queen Fern (N. obliterata) was used. This species was selected because they are one of the common indoor plants used in Iran as well as they are economical and easily accessible. Pots of the plants were bought from commercial distributors (flower market) and kept under laboratory condition at least for a month for acclimatization and watered every 2 days.

Experimental procedures

To investigate formaldehyde removal potential of the plants, experimental procedures were designed and carried out in four stages: (I) “empty chamber tests” without potted plants with a known amount of formaldehyde inlet to determine any combined chamber losses due to (e.g. leakage, absorption and chemical reactions); (II) “whole plant absorption tests” including soil and areal part of the plant by introducing different formaldehyde concentrations to the chamber; (III) “darkness test” to distinct light intensity effects on formaldehyde removal efficiency of the plants; and (IV) soil absorption test (including roots).

Empty chamber losses were assessed before the other above-mentioned experiments. The chamber's combined loss was tested with inlet formaldehyde concentration ranges of 4.5–7 mg/m 3 under two different RH of 40% and 80% for 6 days. Then, two pots of the plants with an average height of 48.4 cm areal part and 17 cm of root part (pot and soil) were placed inside the chamber, to provide sufficient leaf area for optimum air purification. The plants were continuously exposed to formaldehyde vapors with inlet concentrations ranging from 0.5 to 12.0 mg/m 3.[3] The tests for each concentration were carried out 2 days. Among the exposure periods, sampling from inlet and outlet of the chamber was performed every early morning and late evening (4 times for each inlet concentration), and the averages of them were reported. It should be noted that the plant rested for 24 h before starting the next concentration test.

Darkness tests were taken place by covering whole the chamber (entire plants [EPs] inside it) with a black cloth. This test was also carried out for 2 days but only for one of the inlet concentration which laid the median of tested concentrations range (e.g., 4.7 mg m -3). Hereafter, aboveground part of the two other plants with the same pot and areal sizes of those used in the previous tests was surgically removed and the pots containing only soil and roots were put back into the chamber, and then experiments were repeated for an inlet concentration of 5.23 mg/m 3 for 2 days.[3],[27] A new set of plants were used in this stage of experiments to avoid confounding errors as a result of prior formaldehyde exposure.

Plant morphology and physiology

Key characteristics of the plants including morphology and physiology (plant height, leaf area, dry weight, fresh wet weight, chlorophyll content and carotenoid) were evaluated before and after fumigation to assess the effects of formaldehyde on these features as plant growing indices. Chlorophyll content and carotenoid were determined according to Lichtenthaler and Wellburn method.[33] For determination of the individual leaf area, the leaves were counted and categorized as large, medium, and small. Six samples were taken from each category, and their area was measured by a leaf area meter (ΔT Area meter MK2). The average surface area for each category was multiplied by the number of the leaves counted in each category, and the total surface area of each plant was calculated.[2] Furthermore, plant height was measured before and at the end of the experiments. The fresh wet weight of the leaves was determined by the analytical scale and reported in mg/cm 2 of leaf area. Thereafter, the leaves dry weight was measured by drying them in the oven under 80°C for 24 h, weighing out by an analytical scale and reporting in mg/cm 2 of leaf area.

Data analysis

The concentration of formaldehyde in the air flowing to the chamber (CT) was calculated using the following formula:



Where C2 is formaldehyde concentration in the air bubbled from the impinger containing formaldehyde solution, Q1 is the air flow needs for dilution and Q2 is the air flow passing through the formaldehyde solution [Figure 1]. The removal efficiency was calculated using the formaldehyde concentrations entering and leaving the chamber as follow:



The elimination capacity (EC), the amount of formaldehyde vapor removed per unit surface area of plant leaf (mg/m 2/h), was calculated as follow:



Where Cin and Cout are the inlet and the outlet concentrations of formaldehyde (mg/m 3), respectively, Q is the inlet polluted air flow (m 3/h) to the chamber and SL is total leaf area (m 2). Finally, the statistical analyses, drawing the graphs and tables were carried out under Excel software.


  Results Top


Averages of temperature inside and outside the reactor during the experiments were 26.99°C ± 0.84°C and 26.84°C ± 0.81°C, and those for RH were 78.94%±2.25% and 18.885 ± 1.54%, respectively. Background light approaching to the chamber coordinates during daytime was measured and their averages at the measuring time and for whole the study period were calculated. The light intensity was 1795.56 ± 259.29 Lux. There was a difference between the RH inside and the outside the chamber. For the temperature and light intensity, the difference was negligible.

[Table 1] represents the average outlet (Cout) formaldehyde concentrations achieved during the experiment with N. obliterata plant under various inlet formaldehyde concentrations (Cin). Total reduction of formaldehyde by the EP, and by root and soil with and without considering chamber combined losses were also examined. The empty chamber's combined losses tested with inlet formaldehyde concentration ranges of 5.01–6.11 mg/m 3 under two different RH of 40% and 80% were 5.11% and 14.04%, respectively. Thus, in spite of reporting whole removal efficiency, the loss of 14% was deducted from all the results achieved during the experiments and reported as net removal efficiency. Due to a limitation in flow rate for keeping the chamber AER near to 1 time per hour (1 n/h), it was impossible to reduce the chamber RH down to 75%, so we tried to carry out the experiments under an RH of 80% ±5%. EP removal efficiency was examined with ascending inlet formaldehyde concentrations ranging from 0.6 to 11.2 mg/m 3, each for 2 days and the averages of the results were reported [Table 1].
Table 1: Average reduction of formaldehyde vapors achieved by air and root part of Nephrolepis obliterate with and without combined chamber losses

Click here to view


Formaldehyde removal efficiency by potted N. obliterata plant-soil system with and without chamber combined losses, as affected by different inlet formaldehyde concentrations are shown in [Figure 2]a. About 81%–100% of formaldehyde was removed from the polluted air flown into the chamber. The EP net removal efficiencies were calculated by subtracting the chamber combined losses from the whole removal percentages. [Figure 2]b shows the formaldehyde EC of the EP without and with considering the chamber losses.
Figure 2: Formaldehyde removal efficiency (a) and elimination capacity (b) by potted Nephrolepis obliterata plant-soil system with (whole) and without (net) combined chamber losses, as affected by inlet formaldehyde concentrations

Click here to view


Additional experiments were conducted under a thoroughly dark environment to compare the removal efficiency under light versus dark conditions. The plant was exposed to a formaldehyde concentration of 4.7 mg/m 3 for 2 days in a dark environment. The effluent concentrations were measured in the morning and evening of each day, and the average of the results was reported in [Table 1].

The results of plant growing characteristics and their percentage changes after contact with the pollutant were represented in [Table 2]. The most important effects of formaldehyde on the plant were a reduction in the plant wet weight and water content which were reduced by 27% and 5%, respectively. However, the tested concentration of formaldehyde could not abort the plant growth, whereas the chlorophyll content, carotenoid level, and average height of the plants were increased by 9.58%, 21.79%, and 6.46%, respectively, during the fumigation.
Table 2: Morphology and physiology changes of Nephrolepis obliterate during the experiments

Click here to view



  Discussion Top


The results of this study showed that N. obliterata plant-soil system considerably removed formaldehyde vapors from the polluted air during continues long time fumigation. As shown in [Figure 2], about 90%–100% of formaldehyde was removed from the polluted air flown into the chamber with an inlet concentration range of 0.63–9.73 mg/m 3. However, increasing the inlet concentration to 11.09 mg/m 3 within 48 h the removal efficiency was decreased. This shows that the plant could not tolerate with concentrations higher than about 10 mg/m 3. By increasing the inlet formaldehyde concentration and by extending the exposure time the EC was increased. This increase in the elimination rate might be occurred by attribution of plant and soil surface, roots, degradation by microorganisms or bacterial adaption and uptake by the stomas of plant.[27],[33],[34] It has been suggested that when formaldehyde enters the plant through the leaves is firstly detoxified by oxidation then transformed into CO2 and built into the plant material via the Calvin cycle.[35] Depletion of formaldehyde like other VOCs in the chamber which results in slower diffusion rate into the plant is likely to be happened.[27] However, a breakpoint was attained with an inlet concentration of 9.7 mg/m 3. Whereas experiments with an inlet concentration of 11.09 mg/m 3, the EC was not promoted.

In a similar study but with different plants, Xu et al. reported formaldehyde removal efficiencies of about 95% for spider plant-soil system, 53% for Aloe vera-soil system, and 84% for golden pothos-soil system with an inlet concentration range of 1–11 mg/m 3 and at the light intensity of 240 μmol/m 2/s in daytime.[3] It has been reported that the EC by which formaldehyde is removed increases on repeated exposure which is in accordance with our results.[6],[21],[33] According to [Table 1], contributions of the potted soil along with roots in the formaldehyde removal accounted for 26.39% of the total removal by EP. The capacity of potted soils for removal of formaldehyde in the present study was considerably similar to those has been already reported in the literature.[3],[34],[36] This achievement may be attributed to the abundance of soil microbial activity stimulated by root exudate which acts as nutrient for the soil microorganisms.[37] Furthermore, formaldehyde removal capacity increases by the increasing of exposed surface of potted plant.[3]

The results also showed that similar to other studies with the same inlet formaldehyde concentration, removal efficiency under natural daylight was higher than the dark environment. Furthermore, under the same condition but in the days with higher light intensity the formaldehyde removal was higher.[3],[27] Both the stomata and cuticle in the plant leaves could be the pathways for VOC removal. However, it is probably upon on the properties of the VOCs. Formaldehyde is a hydrophilic VOC, therefore could not diffuse through cuticle easily because it consists of lipid.[38],[39] It was, therefore, concluded that formaldehyde was taken up through the stomata as stomata are open in light and closed in darkness.[40],[41] Another explanation can be the increase in the photosynthesis and metabolism rate in daytime leads to more formaldehyde removal compared to night time.[42],[43]

It has been reported in some studies that the removal rate in the first ours is higher and decreases by the passage of time.[44] However, this is only accurate in the batch system not in continues flow system which we applied in our study. This could be an explanation for lower removal efficiency by the EP in higher inlet concentrations after prolonged exposure in our study compared to studies which showed good formaldehyde removal efficiency at high inlet concentration for this species plant-soil system after the shorter exposure period.[10] Increasing of the plant growing characteristics here in our study represented that formaldehyde with an inlet concentration up to 11 mg/m 3 could not stop the plant growth during the fumigation tests. This is likely to be ascribed to the high resistant of the plant against formaldehyde.


  Conclusions Top


Formaldehyde is mainly released to the indoor environment from building materials, home furnishings, and tobacco smoking. The potted N. obliterata plant-soil system examined in this study was talented to the removal of formaldehyde from polluted air in a long time exposure. Although the EP had more contribution in the removal of formaldehyde, the influence of potted soil and roots was considerable which can be attributed to the pollutant absorption and metabolism by the microorganisms in the soils. Formaldehyde EC by the plant increased with elevating the inlet concentrations and reached a plateau with concentrations upper than 11 mg/m 3. EP showed more removal in day time rather than night time and darkness. Examination of the plant morphology and physiology showed that N. obliterata is very resistant to the formaldehyde, whereas long-term exposure could not stop the plant's growth. It is evident from our results that, phytoremediation is one of the most effective, economically and environmental friendly indoor air purification methods which can help improve physical and psychological health.

Acknowledgments

The authors would like to gratefully acknowledge the research chancellery of Isfahan University of Medical Sciences for supporting this work. Grant No: 3941031.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.



 
  References Top

1.
Kabir E, Kim KH. A review of some representative techniques for controlling the indoor volatile organic compounds. Asian J Atmos Environ 2012;6:137-46.  Back to cited text no. 1
    
2.
Aydogan A, Montoya LD. Formaldehyde removal by common indoor plant species and various growing media. Atmos Environ 2011;45:2675-82.  Back to cited text no. 2
    
3.
Xu Z, Wang L, Hou H. Formaldehyde removal by potted plant-soil systems. J Hazard Mater 2011;192:314-8.  Back to cited text no. 3
    
4.
Jones AP. Indoor air quality and health. Atmos Environ 1999;33:4535-64.  Back to cited text no. 4
    
5.
Wang L, Sakurai M, Kameyama H. Study of catalytic decomposition of formaldehyde on Pt/TiO2 alumite catalyst at ambient temperature. J Hazard Mater 2009;167:399-405.  Back to cited text no. 5
    
6.
Wood RA, Burchett MD, Alquezar R, Orwell RL, Tarran J, Torpy F. The potted-plant microcosm substantially reduces indoor air VOC pollution: I. Office field-study. Water Air Soil Pollut 2006;175:163-80.  Back to cited text no. 6
    
7.
Vazquez K, Adams L. The Level of Volatile Organic Compounds Exposure in New Buildings: Can Adding Indoor Potted Plants Reduce Exposure? 2014 NCUR; 2014.  Back to cited text no. 7
    
8.
HE QQ, ZHOU JH. Research advance in purification of formaldehyde-polluted indoor air by potted plants. Acta Agric Jiangxi 2014;2:13.  Back to cited text no. 8
    
9.
Akbar-Khanzadeh F, Park CK. Field precision of formaldehyde sampling and analysis using NIOSH method 3500. Am Ind Hyg Assoc J 1997;58:657-60.  Back to cited text no. 9
    
10.
Kim KJ, Jeong MI, Lee DW, Song JS, Kim HD, Yoo EH, et al. Variation in formaldehyde removal efficiency among indoor plant species. Hort Sci 2010;45:1489-95.  Back to cited text no. 10
    
11.
Colls J. Air Pollution. 2nd ed. Spon Press, London: Clay's library of Health and the Environment; 2002.  Back to cited text no. 11
    
12.
Tang X, Bai Y, Duong A, Smith MT, Li L, Zhang L. Formaldehyde in China: Production, consumption, exposure levels, and health effects. Environ Int 2009;35:1210-24.  Back to cited text no. 12
    
13.
Kim KW, Kim S, Kim HJ, Park JC. Formaldehyde and TVOC emission behaviors according to finishing treatment with surface materials using 20 L chamber and FLEC. J Hazard Mater 2010;177:90-4.  Back to cited text no. 13
    
14.
Park JS, Ikeda K. Variations of formaldehyde and VOC levels during 3 years in new and older homes. Indoor Air 2006;16:129-35.  Back to cited text no. 14
    
15.
Wolverton B, Wolverton JD. Interior plants: Their influence on airborne microbes inside energy-efficient buildings. J Miss Acad Sci 1996;41:99-105.  Back to cited text no. 15
    
16.
Europe WHO. WHO Guidelines for Indoor Air Quality. Selected Pollutants. Copenhagen: WHO Regional Office for Europe Regional Publications; 2010.  Back to cited text no. 16
    
17.
U.S. Department of Health, Human Services. Agency for Toxic Substances and Disease Registry. 2007: Case Studies in Envionmental Medicin-Lead Toxicity ATSDR Publication ATSDR-HE-CS-2001-0001; 2005.  Back to cited text no. 17
    
18.
Sandvik A, Klingen TA, Langård S. Sinonasal adenoid cystic carcinoma following formaldehyde exposure in the operating theatre. J Occup Med Toxicol 2014;9:43.  Back to cited text no. 18
    
19.
Delhoménie MC, Heitz M. Biofiltration of air: A review. Crit Rev Biotechnol 2005;25:53-72.  Back to cited text no. 19
    
20.
Zhao J, Yang X. Photocatalytic oxidation for indoor air purification: A literature review. Build Environ 2003;38:645-54.  Back to cited text no. 20
    
21.
Hajizadeh Y, Rezaei M. Biodegradation of formaldehyde from contaminated air using a laboratory scale static-bed bioreactor. Int J Environ Health Engineering 2014;3:4.  Back to cited text no. 21
    
22.
Mo J, Zhang Y, Xu Q, Lamson JJ, Zhao R. Photocatalytic purification of volatile organic compounds in indoor air: A literature review. Atmos Environ 2009;43:2229-46.  Back to cited text no. 22
    
23.
Xiaojing Z, Shuangyan L, Youju J, Jun W, Huien Z. The comparison of ability of adsorbing formaldehyde among 13 species of indoor ornamentals. Chin Agric Sci Bull 2006;12:054.  Back to cited text no. 23
    
24.
Mudliar S, Giri B, Padoley K, Satpute D, Dixit R, Bhatt P, et al. Bioreactors for treatment of VOCs and odours – A review. J Environ Manage 2010;91:1039-54.  Back to cited text no. 24
    
25.
Liu YJ, Mu YJ, Zhu YG, Ding H, Arens NC. Which ornamental plant species effectively remove benzene from indoor air? Atmos Environ 2007;41:650-4.  Back to cited text no. 25
    
26.
Ou JQ, Zhou JH, Chen SJ, Yue BC. Purification of formaldehyde-polluted air by several potted plants. Northern Hortic 2012;22:22.  Back to cited text no. 26
    
27.
Kim KJ, Kil MJ, Song JS, Yoo EH, Son KC, Kays SJ. Efficiency of volatile formaldehyde removal by indoor plants: Contribution of aerial plant parts versus the root zone. J Am Soc Hortic Sci 2008;133:521-6.  Back to cited text no. 27
    
28.
Sun TR, Cang L, Wang QY, Zhou DM, Cheng JM, Xu H. Roles of abiotic losses, microbes, plant roots, and root exudates on phytoremediation of PAHs in a barren soil. J Hazard Mater 2010;176:919-25.  Back to cited text no. 28
    
29.
Saiyood S, Vangnai AS, Thiravetyan P, Inthorn D. Bisphenol A removal by the Dracaena plant and the role of plant-associating bacteria. J Hazard Mater 2010;178:777-85.  Back to cited text no. 29
    
30.
Korade DL, Fulekar MH. Rhizosphere remediation of chlorpyrifos in mycorrhizospheric soil using ryegrass. J Hazard Mater 2009;172:1344-50.  Back to cited text no. 30
    
31.
Salthammer T, Mentese S, Marutzky R. Formaldehyde in the indoor environment. Chem Rev 2010;110:2536-72.  Back to cited text no. 31
    
32.
Eller PM, Cassinelli ME. NIOSH Manual of Analytical Methods 1994. Cincinnati, USA: DIANE Publishing; 1994.  Back to cited text no. 32
    
33.
Lichtenthaler HK, Wellburn AR. Determinations of total carotenoids and chlorophylls a and b of leaf extracts in different solvents. Biochem Soc Trans 1983;11:591-2.  Back to cited text no. 33
    
34.
Godish T, Guindon C. An assessment of botanical air purification as a formaldehyde mitigation measure under dynamic laboratory chamber conditions. Environ Pollut 1989;62:13-20.  Back to cited text no. 34
    
35.
Schmitz H, Hilgers U, Weidner M. Assimilation and metabolism of formaldehyde by leaves appear unlikely to be of value for indoor air purification. New Phytol 2000;147:307-15.  Back to cited text no. 35
    
36.
Wolverton B, McDonald RC, Watkins E. Foliage plants for removing indoor air pollutants from energy-efficient homes. Econ Bot 1984;38:224-8.  Back to cited text no. 36
    
37.
Xu Z, Qin N, Wang J, Tong H. Formaldehyde biofiltration as affected by spider plant. Bioresour Technol 2010;101:6930-4.  Back to cited text no. 37
    
38.
Riederer M. Partitioning and transport of organic chemicals between the atmospheric environment and leaves. Plant Contamination, Modeling and Simulation of Organic Chemical Processes. London: Lewis Publishers;1995. p. 153-90.  Back to cited text no. 38
    
39.
Trapp S. Fruit Tree model for uptake of organic compounds from soil and air. SAR QSAR Environ Res 2007;18:367-87.  Back to cited text no. 39
    
40.
Treesubsuntorn C, Thiravetyan P. Removal of benzene from indoor air by Dracaena sanderiana: Effect of wax and stomata. Atmos Environ 2012;57:317-21.  Back to cited text no. 40
    
41.
Yoo MH, Kwon YJ, Son K-C, Kays SJ. Efficacy of indoor plants for the removal of single and mixed volatile organic pollutants and physiological effects of the volatiles on the plants. J Am Soc Hortic Sci 2006;131:452-8.  Back to cited text no. 41
    
42.
Hanson AD, Roje S. One-carbon metabolism in higher plants. Ann Rev Plant Biol 2001;52:119-37.  Back to cited text no. 42
    
43.
Haslam R, Rust S, Pallett K, Cole D, Coleman J. Cloning and characterisation of S-formylglutathione hydrolase from Arabidopsis thaliana: A pathway for formaldehyde detoxification. Plant Physiol Biochem 2002;40:281-8.  Back to cited text no. 43
    
44.
Dela Cruz M, Christensen JH, Thomsen JD, Müller R. Can ornamental potted plants remove volatile organic compounds from indoor air? A review. Environ Sci Pollut Res Int 2014;21:13909-28.  Back to cited text no. 44
    


    Figures

  [Figure 1], [Figure 2]
 
 
    Tables

  [Table 1], [Table 2]



 

Top
 
 
  Search
 
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
Access Statistics
Email Alert *
Add to My List *
* Registration required (free)

 
  In this article
Abstract
Introduction
Methods
Results
Discussion
Conclusions
References
Article Figures
Article Tables

 Article Access Statistics
    Viewed814    
    Printed36    
    Emailed0    
    PDF Downloaded125    
    Comments [Add]    

Recommend this journal


[TAG2]
[TAG3]
[TAG4]